Status light on water heater not blinking - Step 1: Pilot Lights, Status Light Flashes. Look at the Status Light on the gas control valve. If the Status Light is flashing more than once every three seconds or not flashing at all, select the appropriate code below. If the Status Light is flashing once every three seconds, the pilot light is lit and the gas control valve is working properly.

 
Make sure the gas supply valve has been turned on. Often something as simple as the gas being turned off can keep a new water heater from working. A newly installed gas water heater will have some air in the gas line. For this reason, it may take several attempts to light the pilot. Many times, the pilot will be lit, but it can be hard to see.. Peddler lufkin texas

The status light lives on top of the main cover. To access the light, you'll need to remove the cover and locate the faceplate panel. Remove the Top Cover. 1. On the back of the unit, unhook the two clips that hold the cover onto the tank below (Figure 1). Flex/pull the cover out and away from the softener at these clips.Bradford White Water Heater Status Light Blinking 7 Times [Solved] The Bradford white water heater blinking light code “7 consecutive flashes with a three-second pause” the indicative of the following facts:First, check that the pilot light is lit. If the pilot light has gone out, you will need to relight it. To do this, turn the gas control knob to the “pilot” setting and hold a lit match or lighter near the thermocouple. You may also need to press and hold the reset button while attempting to …Mar 27, 2022 ... ... 719K views · 8:13. Go to channel · How to fix gas water heater status light not blinking/No hot water fix. Chung•2.3K views · 52:06. Go to...This blinking pattern serves as a reassuring signal that your water heater, including its gas supply and other components, is operating smoothly. The normal heater should have the status light blinking once within 3 seconds. If you see this, you have nothing to worry about because your unit runs normally and well.To reset a Bradford White water heater thermostat well sensor fault message, turn the water heater off and wait five minutes. Turn the knob to ‘Pilot Mode,’ hold the knob down, simultaneously press the button below it until a click is heard, then wait for the ‘Status’ light to blink green. The important thing to remember in this ...The basic method is: Turn the knob to “Pilot Light”. Push in the knob and hold it in. Push the “Pilot Light” button next to the knob. Release the Knob. If all goes well, you should hear some clicking and a whoosh. Now, look underneath the panel, and there should be a little opening so you can see underneath the unit.Here are some of the best outdoor heaters for restaurants to keep your customers warm and cozy when they want to dine outdoors to enjoy a meal. If you buy something through our lin...WATER PRESSURE. Check your home's water pressure with a gauge. The recommended water pressure is 50 to 60 PSIG. If the pressure is higher than that, install a Pressure Regulating Valve (or adjust your existing pressure regulating valve if you have one). For water pressure issues, consult your local water utility or a qualified plumber.How to reset your Honeywell Hot water heater! And don’t forget to check that High Limit Switch!!The status light on a Honeywell water heater can indicate normal operation with a steady on light. Flashing or multiple flashes indicate various fault conditions that require …Water heater not lighting. Water heater too hot. Water Heater hot water smells bad. Water Heater runs out of hot water. Water Heater making noise. Water Heater Maintenance Tips. Free repair help to fix your US Craftmaster water heater. Use our DIY troubleshooting and videos. Then, get the parts you need fast.Jan 28, 2024 · The light on the thermostat turns off and then back again to show that it’s in standby mode, ready for action when needed. 3. Alternate bright and dim. The thermostat called for heat, but it seems like there’s a problem with the tank. You’ll have to check this out and see what caused that. 4. Keep pressing the igniter button while holding down the gas control knob until the status light starts to blink. Look through the viewport to see whether the pilot light comes on or not. Once the pilot light comes on, release the gas control knob and set it to your desired temperature setting.Steps to Resolve Honeywell Gas Control Valve Issues: 2 Flash Code: If there is insufficient power to the gas control valve/thermostat, check all wiring connections. If the problem persists, replace the thermopile. Note that the entire pilot assembly must be replaced when replacing the thermopile. 4 Flash Code: If the temperature has exceeded ...1.1 The Thermostat Problem. 1.2 Pilot Light Out. 1.3 The Empty Tank. 1.4 Power Supply Or The Electrical Issues. 2 The Blinking Water Heater Light Dangerous. …This water heater incorporates a combustion shut off device that shuts the operation of the water heater down if undesirable combustion conditions occur. Page 25: Staus Light Codes Combination Gas Control, Status Light Troubleshooting STATUS LIGHT CODE FLASHES STATUS If the Status Light is not blinking, relight the Pilot.Step 2: Lighting the Pilot. If the Status Light is not flashing, try lighting the pilot using the instructions on the water heater's label. Make sure the gas supply valve is turned ON. When lighting the pilot, make sure the knob on the gas control valve is fully pushed in. Keep the knob pushed in while repeatedly clicking the spark igniter button.If you have a green light on your Honeywell water heater that starts blinking, there are a few possible causes. First, it could be that the pilot light is out. If this is the case, you’ll need to relight it. Second, the blinking could be caused by a problem with the gas line. If you suspect this is the case, you should call a qualified ...So the status light on my water heater is not blinking at all. The pilot is on, the main burner works, and we have hot water. I also checked the voltage on the thermocouple contacts and it's in normal range. What could I be missing? I wonder if the controller itself should be replaced. To troubleshoot a Honeywell water heater without a status light, follow these steps: 1) Check the power supply and ensure it is connected properly. 2) Verify that the circuit breaker is not tripped. If the status light on your water heater is flashing, consult the user manual or contact customer support for further assistance. The light on the thermostat turns off and then back again to show that it’s in standby mode, ready for action when needed. 3. Alternate bright and dim. The thermostat called for heat, but it seems like there’s a problem with the tank. You’ll have to check this out and see what caused that. 4.Jan 29, 2022 ... 13:37. Go to channel · DIY Gas Water Heater Repair - Pilot Light Won't Stay Lit - Status light not blinking. The Hands On Channel•96K views · 7:&...New high-resolution imagery confirm some of the theories about life on Mars, and will help scientists unravel the history of water and ice there. New satellite imagery of jagged sw...Step 01: Drain The Tank. Shut off the power to the heater at the circuit breaker. Close the cold water supply and open a hot water faucet to get rid of the system pressure inside the tank. Connect a garden hose to the drain valve at the bottom of the heater, open the drain valve, and drain the tank.Step 2: Lighting the Pilot. If the Status Light is not flashing, try lighting the pilot using the instructions on the water heater's label. Make sure the gas supply valve is turned ON. When lighting the pilot, make sure the knob on the gas control valve is fully pushed in. Keep the knob pushed in while repeatedly clicking the spark igniter button.Step 1: Tools and Supplies. No tools or supplies are needed for this guide. Step 2: Lighting the Pilot. If the Status Light is not flashing, try lighting the pilot using the instructions on the water heater's label. Make sure …Jan 29, 2022 ... 13:37. Go to channel · DIY Gas Water Heater Repair - Pilot Light Won't Stay Lit - Status light not blinking. The Hands On Channel•96K views · 7:&...Jan 29, 2022 ... 13:37. Go to channel · DIY Gas Water Heater Repair - Pilot Light Won't Stay Lit - Status light not blinking. The Hands On Channel•96K views · 7:&...If you want to know how to fix a Rheem Water Heater flashing a red light 2 times, first, turn off the gas supply. Then disconnect the appropriate wires and remove the Manifold Door. Now, take out the Pilot Assembly and the Thermophile Wire. Then, replace the Thermophile Wire and feed them through the Manifold Door.Turn off the main gas supply to your water heater and set the gas control knob to the “Off” position. Wait for a few minutes for the gas to clear out from the pilot and the main burner area. Turn on the main gas shut off valve and adjust the gas control knob to the “Pilot” position.Here’s how to tell if your water heater pilot light is out: 1. Cold WaterCold water is a dead giveaway that your water heater pilot light isn't working as the water heater pilot light helps with heating the water. While there could be other possibilities, this is typically not the case. 2.1. No hot water. If your water heater’s status light is blinking and you’re not getting any hot water, this is a clear sign that something is amiss. There could be a …Aug 10, 2022 · Flashing the status light on your newly installed heater may require 2-3 lighting attempts. If, after following this method, there is no change in the status light, you must follow the other solutions below: Mainly your heater will not operate when the pilot light is not lit. Mary Richardson breaks down the island's avoidable attractions...and what you should do instead. Mainland Japan is all about efficiency and neon. Elaborate transport systems link d...An interruption or inconsistency in the power supply to the water heater can cause the status light to blink, indicating an electrical issue. 6. Gas Supply Issues. If the heater relies on gas and there are problems with the gas supply, such as a lack of gas or a gas valve issue, it can trigger a blinking status light. To troubleshoot an AO Smith gas water heater, check the limit switch or thermostat for electrical continuity using a multimeter. If the pilot does not light, the water heater will not heat, so make sure there are no carbon deposits restricting the pilot. If the status light is not blinking, try lighting the pilot using the instructions on the ... Bad thermopile. Plus, the tripped thermal switch and clogged air intake filter beneath the heater tank are the other two main culprits that can stop the status light …How To Fix: When you have a 5-time blink on the status light, turn the control knob of the gas valve to the Off position. Right then turn off the gas supply to your water heater as well. Inspect the sensor for any damage and replace it. If needed, replace the faulty gas valve assembly.Give the system 5 minutes to get rid of any build-up gas. Turn the water heat dial to ‘low’ and the pilot dial to ‘pilot’. Turn the pilot dial downwards and simultaneously push the igniter button. Let go of the latter, but keep pushing the pilot button for 30 seconds more. If you have a gas water heater, you might be used to thinking ...January 24, 2023 by David. We’ll cover the following problems in this complete Richmond water heater troubleshooting guide: Condensation. Yellow soot. The main burner won’t light or stay lit. The pilot light won’t stay lit. Rumbling noise. Noise from the relief valve. No hot water or inadequate hot water.Aug 1, 2022 · The Honeywell water heater status light blinking 7 times is a common problem. When the status light blinks red 7 times, it typically indicates a gas valve problem. The gas valve problem typically occurs due to a malfunctioning pilot light, clogged pipes, damaged gas control probe, and faulty gas valve. In order to resolve the Control Board Malfunction: The electronic brain of your water heater might be malfunctioning. Faulty Status Light: The light itself could be burnt out. Wiring Issues: Damaged or loose wiring connections can disrupt communication with the control board. Thermostat Problems: A faulty thermostat might prevent the light from activating.Give the system 5 minutes to get rid of any build-up gas. Turn the water heat dial to ‘low’ and the pilot dial to ‘pilot’. Turn the pilot dial downwards and simultaneously push the igniter button. Let go of the latter, but keep pushing the pilot button for 30 seconds more. If you have a gas water heater, you might be used to thinking ...Here are the three most likely causes plus some troubleshooting tips to assist in correcting the problem: Defective spark electrode – As noted above, more recent model gas water heaters use a spark electrode to automatically light the pilot flame when the pilot setting is selected. If the spark electrode is defective, the pilot won’t light.01 - Water Heater Gas Valve and Thermostat Assembly. The gas valve opens to allow gas to enter the burner. If the gas valve does not open, the burner will not light. First, ensure that the ignition source is working properly. Second, ensure that the gas valve has pressure. If the ignition source is working, and the gas valve has pressure ...Jul 28, 2023 · When the switch is triggered, it can result in a red blinking light indicating a temperature issue. Gas supply issues: If your water heater runs on gas, a red blinking light could signal a problem with the gas supply. This may be due to a gas valve not being fully open, a defect in the gas line, or a lack of gas supply to the unit. Common Causes for a Pilot Light Not Staying Lit: Several potential causes for a pilot light failing to stay lit on a Bradford White water heater. These include a faulty thermopile or thermocouple, a tripped thermal cut-off switch, or a dirty burner assembly. Identifying the root cause is crucial for determining the appropriate troubleshooting ...Do you know how to test a thermocouple on a gas valve? Find out how to test a thermocouple on a gas valve in this article from HowStuffWorks. Advertisement Inside your gas-operated...Welcome to our channel! In this video, we dive into the mysterious world of blinking status lights on Honeywell hot water heaters. If you've ever wondered wh...At a minimum, the attic should have 50 cubic feet of volume per 1,000 Btu/ hr of the total input. For example, if your water heater has an input of 30,000 Btu/hr, the attic should have. a minimum volume of 1,500 cubic feet under normal circumstances. This was calculated as follows: (30,000 ÷ 1,000) 50 = 1,500.With Honeywell wv8840b1153 controller it turned off today, no status light blinking I’ve tried to turn to very hot for 10 seconds, hot 10 seconds and pilot for 10 seconds to reset unit that did not work i waited 10 minutes, tried to light pilot light and held it on pilot for 90 seconds, status light did not turn onContinuous Ignition: While holding the knob, click the igniter button consistently for up to 90 seconds or until the Status Light starts blinking. 3. If the Status Light Doesn’t Blink: Release the knob, wait 10 minutes, and retry. Repeat this process 2-3 times if necessary, waiting 10 minutes between attempts as per the valve’s circuitry.Status light is blinking to indecate high temp shutdown, water heater is not working. Contractor's Assistant: Sometimes plumbing issues that that you think will be really complicated end up being easy to fix. The Plumber I'm going to connect you with knows all the tricks and shortcuts. Tell me a bit more about what's going on so we can …Status light is blinking to indecate high temp shutdown, water heater is not working. Contractor's Assistant: Sometimes plumbing issues that that you think will be really complicated end up being easy to fix. The Plumber I'm going to connect you with knows all the tricks and shortcuts. Tell me a bit more about what's going on so we can … When your Rheem water heater’s blue light flashes, it either indicates that the heater is functioning normally, that the pressure switch is faulty, or that there is a leakage from the heater. Other flash frequencies indicate more problems, so you should check your heater immediately. Source: Rheem water heater flashing code blue 6,3 or 3,6. Note: You can also read how to fix the Honeywell Water heater status light blinking 3 times. Functions Of Thermocouple In Water Heater . The thermocouple is a temperature-measuring sensor that …If the water heater is rusting out or otherwise leaking, you’ll eventually see water pooling around the unit. That’s when you need to turn off the heater and call a professional ASAP. You run the risk of a bigger break and a full-on flood in your house. Do I call a plumber or HVAC repair company? A water heater problem is considered a ... Step 1: Pilot Lights, Status Light Flashes. Look at the Status Light on the gas control valve. If the Status Light is flashing more than once every three seconds or not flashing at all, select the appropriate code below. If the Status Light is flashing once every three seconds, the pilot light is lit and the gas control valve is working properly. I have a Rheem Performance Platinum water heater with a Honeywell gas valve. If I light the pilot, it stays on until I let off of the knob. I do not get any of the Staus indicator lights on the valve. Heater is just over three years old and this is the first issue I have had with it. Either the thermocouple or the pilot solenoid inside the ...Replacing a water heater can be a daunting task, but with the right knowledge and preparation, it can be a smooth process. However, there are some common mistakes that homeowners o...How to Reset Your Furnace. You can reset your furnace by cutting the power to the unit via the service switch or the breaker. Leave it off for about 30 seconds and then turn it back on. This will clear the board and the unit will try to restart so you can watch to see what's happening.Controlled Energy Corp. INSTANTANEOUS WATER HEATER 340 Mad … AQ240FX Water Heater only. Any hot or cold water pipes located outside of the unit will not buttons in heater (58) page 20 for a light.If no light comes on after pushing the test reset Blinking Off 72 Pre post check Computer, Flame rod, gas valve, … Retrieve Full SourceMar 5, 2014 · The status red light stopped blinking and the water heater quit heating water. Turned the Control Knob to Pilot and pressed the knob in and at the same time clicked the Igniter button repeatedly for 90 seconds. Red Status light did not start blinking. Waited 10 minutes and repeated this process maybe 8 or 10 times. Four Reasons The Light On Your Water Heater is Blinking. You can tell which problem you’re having by the color of the light or how often it’s blinking. Of …So the status light on my water heater is not blinking at all. The pilot is on, the main burner works, and we have hot water. I also checked the voltage on the thermocouple contacts and it's in normal range. What could I be missing? I wonder if the controller itself should be replaced.Rheem Gas Water Heater Red Light Code Flashing 1 Time. If your Rheem tankless water heater’s red flashing light is blinking once every 3 seconds, it is in operational mode. It also means the temperature mode is also just fine and in the pilot position. In short, if the light flashes 1 time with a 3-second pause every time, it is …7. Replace it with a new one and put the removed parts back together in reverse order. 2. Faulty Gas Control Valve. A blinking status light on your water heater could also indicate a faulty gas control valve. This could also …Jan 24, 2023 · Here’s a shortcut on how to solve the five flash issue: 6. Six-One Flash Three Seconds Pause. This blinking light code indicates that the ignition has failed and the heater won’t light up. The most common reason behind it is having a poor gas supply that’s not sufficient to light the heater. Jan 26, 2022 ... Our Honewell gas water heater started flashing status 10 - clean burner screen, pilot light went out. No hot water...Easy 1min fix.#Honeywell #waterheater #honeywellstatusmeterA blinking SMS message grabs your recipient's attention almost immediately by landing and blinking on his cell phone screen instead of in his phone's SMS inbox. You can either blin...When the switch is triggered, it can result in a red blinking light indicating a temperature issue. Gas supply issues: If your water heater runs on gas, a red blinking light could signal a problem with the gas supply. This may be due to a gas valve not being fully open, a defect in the gas line, or a lack of gas supply to the unit.If you have a Honeywell water heater in your home, you may have noticed a small light on the front of the unit. This light is the status light, and it can be one of three different colors: green, red, or orange. Here’s what each color means: Green: The water heater is operating normally. Red: There is a problem with the water heater.Step 1: First turn the gas control knob to the off position. Unplug your heater from the power cord and shut off the gas shut-off valve. Step 2: Remove the combustion chamber cover panel. Then detach the burner assembly from the gas valve and gently slide the assembly out from the combustion chamber.Mar 7, 2024 · If you have a green light on your Honeywell water heater that starts blinking, there are a few possible causes. First, it could be that the pilot light is out. If this is the case, you’ll need to relight it. Second, the blinking could be caused by a problem with the gas line. If you suspect this is the case, you should call a qualified ... The most common problem is a dirty flame sensor which can behave like this (sometimes it works sometimes it doesn't). If rebooting the heater (like you just did) doesn't get it working again you'll probably have to call a plumber to come out and check it …Step 9 Light the Pilot. Try lighting the pilot using the instructions on the water heater's label. If after following these troubleshooting steps the Status Light still flashes two times every three seconds, turn the gas control knob OFF, turn the gas supply valve OFF, and click on "Need More Help" below. Add a comment.1. Blue Light. 2. White Light. 3. Red Light. Why Is My Honeywell Water Heater Status Light Not Blinking? No Pilot Light. No Spark In Igniter. Tripped Thermal Switch. Gas Supply Issue. Faulty Gas Control Valve. How To Reset Honeywell Water Heater-Step By Step. Honeywell Gas Water Heater Reset Button. Final Words. Related posts:When this happens, the Rheem water flashes blue light three times. #2. Twisted Vacuum Tube. A vacuum tube attaches to the pressure switch on top of your heater. Once this tube gets kinked or twisted, the heater flashes blue light to signal you. #3. Problems with the Flammable Vapor Sensor.Here Here’s how to light the pilot light on a Rheem gas water heater. On a modern Rheem gas water heater, it is very easy to light the pilot light. First, tu...Welcome to our channel! In this video, we dive into the mysterious world of blinking status lights on Honeywell hot water heaters. If you've ever wondered wh...WATER PRESSURE. Check your home's water pressure with a gauge. The recommended water pressure is 50 to 60 PSIG. If the pressure is higher than that, install a Pressure Regulating Valve (or adjust your existing pressure regulating valve if you have one). For water pressure issues, consult your local water utility or a qualified plumber.Jun 23, 2018 ... ... 212K views · 8:13. Go to channel · How to fix gas water heater status light not blinking/No hot water fix. Chung•2.3K views · 4:00. Go to&...Lighting The Gas Valve – Reliance Water Heaters Once the red status light is blinking, release the We recommend a maximum temperature setting of HOT (120°F) to reduce the risk of scalding. See the water heater’s labels for important safety information. With a new water heater, it may take 2-3 attempts before the pilot lights. … Read Document1. No hot water. If your water heater’s status light is blinking and you’re not getting any hot water, this is a clear sign that something is amiss. There could be a …Aug 1, 2022 · The Honeywell water heater status light blinking 7 times is a common problem. When the status light blinks red 7 times, it typically indicates a gas valve problem. The gas valve problem typically occurs due to a malfunctioning pilot light, clogged pipes, damaged gas control probe, and faulty gas valve. In order to resolve the

The Honeywell water heater status light blinking 7 times is a common problem. When the status light blinks red 7 times, it typically indicates a gas valve problem. The gas valve problem typically occurs due to a malfunctioning pilot light, clogged pipes, damaged gas control probe, and faulty gas valve. In order to resolve the. Pippa pipkin face

status light on water heater not blinking

Oct 29, 2020 ... Might be obvious to most but it took me a minute to future out - especially because there was no mention about the ~15s wait for the green light ...If the status light on Honeywell Gas Control Valve is blinking 6 times, understand there is a leak detected on the tank by the accessory module. Turns out, the 6-consecutive flash every 3 seconds indicates the burner is at fault. How To Fix: First off, check the tanke of the water heater to find a leak. If you find a leak, fix it.Step 1: Reset the Thermal Switch. The thermal switch can trip if the water heater is not getting enough air. Press the small reset button in the center of the thermal switch. If it's tripped, you may be able to hear it click. Even if you do not hear the thermal switch click, try lighting the pilot using the instructions on the water heater's label.Feb 2, 2024 · Let’s see which one is the reason for your concern. Table Of Content hide. 1 Why Honeywell Hot Water Heater No Status Light: Better Suggestions. 1.1 Dirty Base Ring And Pilot. 1.2 Solve The Igniter Faulty. 1.3 Tangle In The Flex Tube. 1.4 Defective Thermocouple. 1.5 Control Board Fails. 2 This Video Will Help You Too! Bradford White Water Heater Status Light Blinking 7 Times [Solved] The Bradford white water heater blinking light code “7 consecutive flashes with a three-second pause” the indicative of the following facts:First, check that the pilot light is lit. If the pilot light has gone out, you will need to relight it. To do this, turn the gas control knob to the “pilot” setting and hold a lit match or lighter near the thermocouple. You may also need to press and hold the reset button while attempting to … Step 1: Pilot Lights, Status Light Flashes. Look at the Status Light on the gas control valve. If the Status Light is flashing more than once every three seconds or not flashing at all, select the appropriate code below. If the Status Light is flashing once every three seconds, the pilot light is lit and the gas control valve is working properly. Apr 23, 2014 ... Ibanlira•89K views · 8:13 · Go to channel · How to fix gas water heater status light not blinking/No hot water fix. Chung•2.3K views · ...Replacing a water heater can be a daunting task, but with the right knowledge and preparation, it can be a smooth process. However, there are some common mistakes that homeowners o...Feb 2, 2024 · Let’s see which one is the reason for your concern. Table Of Content hide. 1 Why Honeywell Hot Water Heater No Status Light: Better Suggestions. 1.1 Dirty Base Ring And Pilot. 1.2 Solve The Igniter Faulty. 1.3 Tangle In The Flex Tube. 1.4 Defective Thermocouple. 1.5 Control Board Fails. 2 This Video Will Help You Too! The water heater carries a 9-year warranty on parts but only one-year warranty on labor. It is a good thing I have a second 40-year old heater that is still working perfectly. This gives me time to deal with the Kenmore problem. I am shopping for another water heater but definitely NOT A KENMORE. Never again Id buy anything from Sears …First, check that the pilot light is lit. If the pilot light has gone out, you will need to relight it. To do this, turn the gas control knob to the “pilot” setting and hold a lit match or lighter near the thermocouple. You may also need to press and hold the reset button while attempting to light the pilot.Follow these steps to test the thermopile: Turn off the gas control valve in your water heater and give it some time to cool down. Set your multimer to DC mode and change the settings to millivolts. Remove the thermopile wiring connector from the gas control valve. You may have to push it back and forth to get it out.No Hot Water (Status Light Not Flashing) Check status light on gas valve. The pilot must be lit for the status light to flash. If status light is not flashing, try relighting the pilot using instructions on water heater. The pilot can be hard to see, so you may need to dim the room lights. Status Light Doesn't Flash (Electrical Problem) If the ...1. Weak Fan. One of the major reasons behind the Honeywell water heater light blinking 3 times is due to the weak performance of the fan. This typically occurs when the motor is faulty or the blades are clogged. If the fan doesn’t work properly, then the pressure switch won’t be able to detect the signal. This will prevent the water heater ...1. Check the thermostat. You should operate your water heater -- whether it is gas or electric -- at 120 to 140 degrees Fahrenheit ( setting it at 120 will save some energy ). If your thermostat...Sep 24, 2011 ... 13:37. Go to channel · DIY Gas Water Heater Repair - Pilot Light Won't Stay Lit - Status light not blinking. The Hands On Channel•96K views · 10&....